>Hi. Hoping someone can help me. I am in contract to purchase a farm
>and I just had the water tested. Coliform 23+ and ecoli 5.1. The
>farm is fed by two springs (no well) and one spring exclusively
>feeds the field and the other goes into the house (and so a UV
>bulb wouldn't help).
in DRINKING water there shouldn't be ANY ecoli ! otherwise i would
not ask you for a glass of water.
but the numbers do look a bit strange to me. coliform 23+ ? there
is no further information on the analysis certificate ? something
like 23 * 10^5 (or 10^6 ?) colony forming units ? found in what
volume of water ?? 100 ccm or 1 liter or one gallon ?
>is there any cheap solution to this problem?
mostly there isn't. you will have to find the source of the
contamination (breaking-down of the walls of the well ?). before
you do not know the source, you can only guess about the costs.
Klaus Wiegand
Landwirtschaftl. Untersuchungs- u. Forschungsanstalt (LUFA)
(Governm. Inst. for Agricult. & Environm. Res.)
67346 Speyer, Obere Langgasse 40 (GERMANY)
Dept. of Seed Sci., Microscop. Analysis & Plant Pathol.